HEBHMUi018-A

The cell line is not validated yet.

General

Cell Line

hPSCreg name HEBHMUi018-A
Cite as:
HEBHMUi018-A
Cell line type Human induced pluripotent stem cell (hiPSC)
Similar lines No similar lines found.
Last update 2nd July 2024
User feedback
No feedback available yet.

Login to share your feedback, experiences or results with the research community.

Provider

Generator Hebei Medical University (HEBHMU)
Owner Hebei Medical University (HEBHMU)
Distributors
Derivation country China

External Databases

BioSamples SAMEA115793210

General Information

* Is the cell line readily obtainable for third parties?
No

Donor Information

General Donor Information

Sex male

Phenotype and Disease related information (Donor)

Diseases A disease was diagnosed.
The donor is a carrier of a disease-associated mutation and affected.
Family history yes

Karyotyping (Donor)

Has the donor karyotype been analysed?
No

External Databases (Donor)

BioSamples SAMEA115793211

Ethics

Has informed consent been obtained from the donor of the embryo/tissue from which the pluripotent stem cells have been derived? Yes
Was the consent voluntarily given? Yes
Has the donor been informed that participation will not directly influence their personal treatment? Yes
Can you provide us with a copy of the Donor Information Sheet provided to the donor? Yes
Do you (Depositor/Provider) hold the original Donor Consent Form? No
If you do not hold the Donor Consent Form, do you know who does? Yes
Please provide the contact information HEBEI MEDICAL UNIVERSITY
Please indicate whether the data associated with the donated material has been pseudonymised or anonymised. anonymised
Does consent explicitly allow the derivation of pluripotent stem cells? Yes
Does consent prevent CELLS DERIVED FROM THE DONATED BIOSAMPLE from being made available to researchers anywhere in the world? No

Does consent permit research by

an academic institution? Yes
How may genetic information associated with the cell line be accessed? Controlled Access
Will the donor expect to receive financial benefit, beyond reasonable expenses, in return for donating the biosample? No
Has a favourable opinion been obtained from a research ethics committee, or other ethics review panel, in relation to the Research Protocol including the consent provisions? Yes
Name of accrediting authority involved? Ethics Committee of Hebei Medical University
Approval number HEBHMU-20190017
For generation of the cell line, who was the supplier of any recombined DNA vectors or commercial kits used?

hIPSC Derivation

General

Source cell type

Reprogramming method

Vector type Non-integrating
Vector Sendai virus
Is reprogramming vector detectable?
Yes
Methods used
PCR

Vector free reprogramming

Other

Derived under xeno-free conditions
Unknown
Derived under GMP?
Unknown
Available as clinical grade?
Unknown

Culture Conditions

Surface coating Matrigel/Geltrex
Medium Essential 8™

Characterisation

Analysis of Undifferentiated Cells
Marker Expressed Immunostaining RT-PCR Flow Cytometry Enzymatic Assay Expression Profiles
Differentiation Potency
Hepatocyte
Ont Id: CL_0000182
Smooth Muscle Cell
Ont Id: CL_0000192
Neuron
Ont Id: CL_0000540

Genotyping

Karyotyping (Cell Line)

Has the cell line karyotype been analysed?
Yes
44+XY
Passage number: 14
Karyotyping method: G-Banding

Other Genotyping (Cell Line)